Line Loss Lean Management

The key to grid loss analysis lies in the strategic deployment of metering devices and the accurate collection of energy data. The lean loss management solution enables the following:


  1. By deploying various boundary meters at key nodes in transmission and distribution networks, the system supports loss detection, multi-directional power flow topology analysis, and the establishment of an independent automatic meter reading (AMR) system. This allows for precise evaluation of grid losses.

  2. Taking the distribution transformer area as the core, the solution includes dedicated metering for large power users, boundary metering for public transformers, as well as residential and commercial user metering. Energy data is collected and analyzed at the transformer area level to enable accurate and granular loss statistics.


APPLICATION SCENARIO

xitongxiansunjingyihuaguanli.png

RELATED PRODUCTS

  • IHM6500FLW34SF6LoadBreakSwitch.png
    IHM-6500-FLW34 SF6 Load Break Switch SERIES

    IHM-6500-FLW34 series SF6 Load Break Switch use on distribution lines for all voltage classes rated up to 40.5kV(12kV, 24kV,40.5kV) at 50/60Hz power system. It uses for opening or closing the load currrent and closing short circuit current.


    IHM-6500-FLW34 adopts SF6 arc extinguishing, SF6 insulation. It can be open or close by manual or electric.


  • IHM6500ZW32VacuumCircuitBreaker.png
    IHM-6500-ZW32 Vacuum Circuit Breaker SERIES

    IHM-6500-ZW32 series vacuum circuit breakers use on distribution lines for all voltage classes rated up to 38kV(15kV, 27kV, 38kV) at 50/60Hz power system. It uses for opening and closing the load current, overload current and short circuit current.


    IHM-6500-ZW32 uses spring operating mechanism, it can be open or close by manual or electric. It can be pole mounted or ground mounted and suitable for overhead line and substation.

    IHM-6500-ZW32 has the characteristics of small size, light weight, anti-condensation and maintenance-free, which can be used in harsh environment.


  • AutoRecloser1.png
    Auto Recloser SERIES

    IHM-6500-AR series auto recloser is a new generation of product developed to satisfy the demand of switchgear for rapid developing smart distribution network. IHM-6500-AR recloser and IHM-6500-LBS line sectionalizer cooperate to realize automatic isolation of the faulty section of the distribution line and achieve the feeder automation function. Reclosers are installed at the head of distribution lines, the head of large branches or the incoming side of users to achieve rapid local isolation of faults, and cooperating with sectionalizers to achieve sectional isolation to reduce the scope of power outages. It is widely used in ring power supply lines, radioactive lines, branch lines and end-user feeders. Reclosers can connect with SCADA to complete fault location, safe power supply transfer control, and load management etc. 


    The IHM-6500-AR Auto Recloser is equipped with a multi-interface and multi-protocol communication system, catering to both debugging and remote control needs for efficient data interaction in different scenarios. Specifically, it has:
    1.Front Panel RJ45 Ethernet Port: IEC104 protocol for debugging; 

    2.Rear Panel RS232 & RS485/232 Serial Port: IEC101/DNP3.0/Modbus for remote; 

    3.Rear Panel RJ45 Ethernet Port: IEC104/DNP3.0/Modbus for remote.


    • MultiProtocol.png

      Multi-Protocol

    • OverloadProtection.png

      Overload Protection

    • PhasetoPhaseShortCircuitProtection.png

      Phase to Phase Short Circuit Protection

    • Reclosing.png

      Reclosing

  • zhushangkaiguanPoleMountedSwitch7852.png
    Auto Sectionalizer SERIES

    INHE's Auto Sectionalizer adopts SF6 dielectric insulation technology. It works together with recloser to further improve feeder reliability. It can be used in the main line of distribution network, branch line or at user boundary. It detects fault and automatically isolates faulty sections of a network in conjunction with recloser operation. It also senses current and voltage to count the number of recloser trip operations. When the preprogrammed number of recloser operations is reached, the sectionalizer opens during the recloser dead time to isolate the downstream fault.


    INHE's Auto Sectionalizer can be used on overhead distribution lines for all voltage classes rated up to 40.5kV(12kV, 24kV, 40.5kV) at 50/60Hz power system.


    • MultiProtocol-300.png

      Multi-Protocol

    • FaultCounting.png

      Fault Counting

    • OnLineFaultDetection-418.png

      On-Line Fault Detection

01

03

SOFTWARE SUPPORT

  • Smart AMI

    The Smart AMI system integrates communication, IoT, and cloud tech to manage data collection, monitoring, and analysis. It organizes data from substations, lines, transformers, and users, enabling real-time monitoring and supporting load control, energy purchasing, and power management.

    • SoftwareSmartAMIDiverseequipmentsupport-89.png

      Diverse equipment support

    • SoftwareSmartAMIVersatilecommunicationmethods-972.png

      Versatile communication methods

    • SoftwareSmartAMITaskbasedremotedatacollection-584.png

      Task-based remote data collection and configuration

    • SoftwareSmartAMIRealtimeequipmentmonitoring-414.png

      Real-time equipment monitoring

    • SoftwareSmartAMIVarieddataanalysisoptions-262.png

      Varied data analysis options and reports

    • SoftwareSmartAMIMapintegratedonsitemobileHHU-97.png

      Map-integrated on-site mobile HHU

    AMI1800x975337-94.png
b2bg02.svg

01

02